Objeto
VAP Moisture Mitigation System in Plymouth Factory 
Campos de aplicación
Inyección de grietas por inyección a presión en grietas secas o húmedas
Moisture Mitigation System
Descripción
Repair of a section of flooring badly affected by osmotic blistering. Problem fully investigated by taking test core sample and after analysis Koster Aquatecnic advised on a bespoke solution using Koster VAP 2000 FS to solve the problem of water vapour rising through the concrete slab and destroying the bond between the slab and the adhesive coating. The first step was to fill all cracks, potholes and voids with VAP FS 2000 and then shot blast and thoroughly clean the concrete slab. KB Pox IN was then used as a pre-treatment and finally, VAP 2000 FS was applied to a thickness of 0.36mm. VAP is a fast setting vapour barrier and can be over-coated in 2-3 hours allowing for overnight application.  
Producto aplicado
KÖSTER KB-Pox IN
KÖSTER KB-Pox Thickening Agent
KÖSTER VAP I 2000 FS
Contratista
Florock Ltd 
Selecciona producto:

 

 

Back

Top
Albania Bosnia and Herzegovina Brasil Bulgaria China Colombia Croatia Czech Republic Denmark Finland Germany Greece Iraq Italy Japan Kazakhstan Kuwait Latvia Lebanon Macedonia Mexico Netherlands New Zealand Panama Poland Portugal Romania Serbia Slovakia Slovenia South Africa Spain Turkey Ukraine United Kingdom United States of America